March 30, 2004
Berkeley Lab Research News
Bay Area To Get Unique X-Ray Microscopy Resource
Lab news releases

Sign up to receive our news releases via email

Science Beat: most recent science news here

Berkeley Lab home page

Lab A to Z website index

Search news articles archive
 
 Advanced Search  
Search Tips

BERKELEY, CA —  A first-of-its-kind x-ray microscope being built for the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory (Berkeley Lab) holds forth the promise of “cat scans” for biological cells, and other unprecedented capabilities for cell and molecular biology studies. The new microscopy resource also promises a better understanding of human diseases at the molecular level and possibly new discoveries for treating those diseases. Now, researchers with Berkeley Lab and the University of California at San Francisco (UCSF), have received grants from the National Institutes of Health (NIH) and the U.S. Department of Energy (DOE) to build and operate this microscope.

“X-ray microscopy is an emerging new technology that will expand the existing imaging toolbox for cell and molecular biologists, and we would like to make this technology available to the greater biological community,” says cell biologist and microscopy expert Carolyn Larabell, who holds a joint appointment with UCSF’s Anatomy Department, and with Berkeley Lab’s Physical Biosciences Division. She is the principal investigator for this project. Berkeley Lab physicist Mark Le Gros is the co-principal investigator.

This x-ray tomography image of a yeast cell taken at the ALS with XM-1 is an example of what could be done with the proposed XM-2. Internal organelles are color-coded according to x-ray absorption. Shown in red are the nucleus (smaller sphere) and large vacuole. Lipid droplets are shown in white, and cytoplasmic structures are shown in either orange or green.

“Although there are currently many powerful techniques for imaging biological cells, each with its own unique strengths and limitations, there remains a gap between the information that can be obtained with light microscopy and electron microscopy,” Larabell says. “X-ray microscopy can bridge this gap by combining some of the best features associated with light and electron microscopy, plus bringing in some entirely new capabilities.”

To build this new microscope, Larabell and Le Gros have been awarded $2.5 million from NIH and DOE. The money will be dispersed to UCSF through NIH’s National Center for Research Resources (NCRR) and directly to the Berkeley Lab through the DOE Office of Science's Biological and Environmental Research Program (BER). Under the terms of this grant, Larabell and Le Gros will establish a Biomedical Technology Resource Center at the ALS, which means the instrument will be available to biomedical researchers throughout the nation. The new ALS x-ray microscopy resource will be the first of its kind and the 43^rd such center sponsored by NCRR. Together, NIH and DOE will contribute about $1.3 million to run the microscopefor each of its first five years of operation. The grants can then be renewed for additional five-year periods.

What Larabell and Le Gros have proposed is a transmission x-ray microscope (TXM) off a bend magnet beamline at the ALS, an electron-based synchrotron/storage ring capable of generating x-ray beams that are one hundred million times brighter than those from the best x-ray tubes. With beams of this intensity, the new TXM will be able to image whole, hydrated cells at resolutions of about 35 nanometers, and specific structural elements within the cell at a resolution of at least 25 nanometers. Future improvements could put the resolution of this microscope as fine as 10 nanometers, which is about the size of a protein.

Imaging data will be collected at breathtaking speed compared with the time-consuming procedures required to collect data via electron microscopy. Obtaining a complete data set for an x-ray tomography image should require less than three minutes, compared to the days and even weeks required for electron microscopy.

“We’ll be able to collect data faster than we can process it,” Larabell says. “We’ll be able to examine whole cells, identify subcellular components and locate macromolecules inside cells at substantially better resolutions than light microscopy and without the elaborate specimen preparations needed for electron microscopy.”

Microscopy using photons that fall within the visible light region of the electromagnetic spectrum remains the workhorse of biology because it enables scientists to examine living cells in their natural state. Resolution, however, is typically no better than 200 nanometers, and that is only when the light is focused on a single spot.

Microscopy techniques based on the use of electrons can provide images at a resolution of five nanometers or better. However, samples must be sliced thin and put through an elaborate chemical preparation and stained in order for the electrons to penetrate and yield high-res images.

With transmission x-ray microscopy, samples are rapidly frozen and need no further chemical alteration or staining to be imaged. Furthermore, 3-D subcelluar structures within 10 nanometers of one another can be captured in the same image, which means interactions between two or more proteins can be observed. Because of the quick turnaround time between sample preparation and data collection, scientists using the new TXM at the ALS will be able to accumulate a statistically significant volume of data within a relatively short time.

Carolyn Larabell and Mark Le Gros used the current transmission x-ray microscope at the ALS, XM-1, to demonstrate the potential of their new microscopy resource.

Larabell and Le Gros have been using an existing TXM at the ALS to demonstrate the potential of using this technology in cell and molecular biology studies. The existing TXM, called XM-1, the only one of its kind in the United States, was designed and is operated by the Center for X-ray Optics primarily for the study of materials. The new TXM, dubbed XM-2, will be optimized for biology and will therefore have several advantages, including improved zone plates, the optic devices composed of nanometer-scale concentric metal rings that are used to focus x-rays for imaging purposes.

“Whereas XM-1 could only be used to study suspension cell lines, XM-2 can be used to study adherent cell lines as well,” says Larabell. “In addition, we’ll have greater energy tunability with XM-2 which means it can be used to do imaging of thicker samples as well as high-res images of thinner samples just by spinning to a different zone plate.”

XM-2’s ability to use a multiple choice of x-ray beam energies will also open the door to multiple labeling of proteins. This means scientists will be able to use the microscope to study protein complexes as well as individual proteins. XM-2 should also prove to be a powerful tool for utilizing tomographic imaging techniques in x-ray microscopy. In a study using XM-1, Larabell and Le Gros performed CT scans of whole, rapidly frozen yeast cells and obtained 3-D reconstructions at a resolution of better than 50 nanometers.

“No contrast enhancement reagents were used, the cells were not embedded or sectioned, and collection of the entire data set took less than an hour,” says Larabell. “While our resolution was not quite as good as that from cryo-electron tomography, it was more than sufficient for many of the scientific questions being asked. Also, we’ve not yet reached the limit of resolution that’s theoretically possible with x-ray tomography.”

Under the terms of the NIH-NCRR and DOE-BER funding, XM-2 is expected to be up and running at the ALS in 2006.

Berkeley Lab is a U.S. Department of Energy national laboratory located in Berkeley, California. It conducts unclassified scientific research and is managed by the University of California.

Additional Information

Top